AAG skydome NO FRAME
AAG wing overview and technical data
Reaction to fire | Class |
Heat transfer coefficient - glazing | Ut |
Heat transfer coefficient - skydome withou upstand | Ur |
Heat transfer coefficient - skydome with upstand | Urc |
Upward load | UL |
Downward load | DL |
Resistance to pendulum impact | 1B1 |
Air permeability | AP |
Sound transmission loss | Rw |
Watertightness | Comply |
Hard body impact | Comply |
Radiation properties | tD65 /g |
-
Comfortable glazing NO FRAME
- skylight filling - insulated safety triple glazing ESG Energy 4-14-4-16-33.2 (6-14-4-14-44.2) around the perimeter with a darkened overlap and a ground edge
Reaction to fire:with upstand from steel = A1, with upstand from PVC = EHeat transfer coefficient Ut/Ur/Urc = 0,6/0,93/0,92(1,2) W/m2.KRadiation properties (tD65/g) = 73%/0,55UL = 1500, DL = 2500, 1B1, AP 4, Rw = 42 dB -
Underlying PIR frame with slope
- Thermally insulating PIR frame for installation under the skylight upstand to achieve a skylight slope of min. 5°
- material: purenit sandwich (30 mm purenit + 30 mm puren PIR core + 30 mm purenit)
- Třída reakce na oheň E
Thermally insulated frame for achieving a 5° skylight inclination. Designed for installation on a building opening.
Important informationí:
Any breakage of the glass after the customer has received the delivery of the skydome, whether during onward transport, storage, on the transport frame, during assembly and handling or installation on site, or breakage of the glass due to thermal shock or climatic fracture etc. are not subject to a claim and cannot be accepted.
To prevent dirt from settling on the skylight filling, we recommend using a glazing dome or a PIR base frame with a slope for applications with a skylight placement of up to 5° for glass fillings and for polycarbonate (PC) fillings.
Because of snow overload (there is a danger of glazing collapsing and leaking) of flat glass and flat polycarbonate (PC) glazing, it is necessary to regularly clean snow from the skydome surface.
Follow the instructions for skydome snow load measurements. download here